Core Technology & Architecture

CPM & Smart Sensor Architecture

One weak module can drag down a whole string and it is nearly impossible to find without module-level telemetry. CPM makes it trivial.

INTELLIGENT FIELD TELEMETRY & DIAGNOSTIC OPERATIONS CONSOLE

Field Site CAD & Satellite Array Overlay • 3-Tier Module Classification (Good / Marginal / Failed) • Rapid Safety Control

INITIALIZING STREAM...
Plant Monitored: 2.4 MWp Field Array

FIELD SITE LAYOUT PLAN (MACRO VIEW)

Field site plan background • Focuses on selected sector modules

Plan View:
HV/MV Substation Solar CAD Layout Plan
NORTH ↑| 33.918°N, 118.384°W
CONSOLE FOCUS: SECTOR B-04
96 MODULES IN ACTIVE TELEMETRYHV SUBSTATION STRING #03
● Focused Section:Sector B-04: Central Substation & High-Yield PV Strings
Scale: 1:500OEM Target: 650 W / Commercial ModuleString: 1,000 V (1000V–1500V DC)Sector Yield: 94.2%

SECTOR B-04 MODULE PERFORMANCE MATRIX

650W Large Format Modules • 1,000V DC String Architecture • Click or hover any module to inspect live telemetry

Good Modules:

> 85% of OEM output (Optimal)

Marginal Performers:

75% - 85% of OEM (At-risk)

Failed Modules:

< 75% or 0W output (Critical)

Active Focus: Inverter String #03 (24 Modules in Series • 1,000V DC Active String)99.98% Telemetry Packet Integrity
INSPECTING MODULE

MOD-B04-R01-C01

Row 1 • Column 1 • String #03 (1,000V DC)

GOOD (>85%)
OEM Performance Ratio:98.2% of OEM
0%75% (Marginal Cutoff)85% (Good Baseline)100%
Active Output
638.3W
OEM Rated: 650.0 W
String Voltage
1000.0V
1000V–1500V String Std
Module Voltage
41.2V
Vmpp Nominal: 41.2V
Operating Current
15.75A
Impp Nominal: 15.8A
Cell Temperature
45.4°C
Ambient: 28.5 °C • UL 1741 PVRSS Monitored
Diagnostic Insight:

Optimal cell string performance & impedance matching

Recommended O&M Action: No maintenance required. Healthy nominal generation.
Live Field Telemetry Stream Active
FOCAL SECTOR: ZONE B-04 (96 MODULES)IRRADIANCE: 1000 W/m²TEMP: 25.0°C

The Core Problem

Series strings hide failures in aggregated averages.

In a standard solar string, 24 modules are wired in series. If one module degrades by 30%, string current drops proportionally but the inverter only reports total string output. The fault is invisible.

A CPM Smart Sensor on every module converts invisible degradation into an instant GPS-tagged field ticket eliminating hours of manual IV-curve tracing and thermal drone flights.

Series String Model: 8 Modules

100%
M1
100%
M2
30%
M3
100%
M4
100%
M5
100%
M6
100%
M7
100%
M8
Module M3 Operating at 30% — String Power Loss: ~8.7%
CPM detects and pinpoints M3 within 3 seconds

System Architecture

The CPM data pipeline.

Stage 1 of 5

Smart Sensor Hardware

Edge Intelligence Layer

CPM Smart Sensors attach directly to each PV module terminal. They sample voltage, current, temperature, and irradiance at sub-second intervals across the entire string.

Sampling Rate: 10Hz continuous
Voltage Range: 0–60V DC
Temperature: -40C to +85C
IP67 Weatherproof enclosure
25-year design lifetime

Fault Detection Library

14+ automatically classified fault modes.

01
Micro-crack Detection
02
Bypass Diode Failure
03
Cell Hotspots
04
PID Degradation
05
LID Degradation
06
Soiling Accumulation
07
Module Mismatch
08
Interconnect Corrosion
09
Partial Shading
10
Snail Trail Contamination
11
Delamination
12
Solder Bond Fracture
13
Junction Box Overheating
14
String Current Mismatch